{"id":3515,"date":"2024-09-10T20:03:09","date_gmt":"2024-09-10T18:03:09","guid":{"rendered":"https:\/\/endolab.org\/?post_type=vi-stents-and-endova&#038;p=3515"},"modified":"2025-06-24T17:22:28","modified_gmt":"2025-06-24T15:22:28","slug":"iso-25539-2","status":"publish","type":"vi-stents-and-endova","link":"https:\/\/endolab.org\/de\/vi-stents-and-endova\/iso-25539-2\/","title":{"rendered":"ISO\u00a025539"},"content":{"rendered":"<p><strong>ISO&nbsp;25539-1:2003:<\/strong>&nbsp;Cardiovascular implants \u2014 Endovascular devices \u2014 Part 1: Endovascular prostheses<\/p>\n\n\n\n<p><strong>ISO&nbsp;25539-2:2012:<\/strong>&nbsp;Cardiovascular implants \u2014 Endovascular devices \u2014 Part 2: Vascular stents<\/p>\n\n\n\n<p>The local compression test determines the deformation of the device in response to a localized compressive force and whether the stent recovers its original geometry after testing. Using a probe, the load is applied perpendicular to the longitudinal axis of the device, and the load versus displacement curve is recorded. This test has been withdrawn and is no longer included in the updated standard.<\/p>\n\n\n\n<p><\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":true,"_uag_custom_page_level_css":""},"class_list":["post-3515","vi-stents-and-endova","type-vi-stents-and-endova","status-publish","hentry"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Kilian Pallauf","author_link":"https:\/\/endolab.org\/de\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO&nbsp;25539-1:2003:&nbsp;Cardiovascular implants \u2014 Endovascular devices \u2014 Part 1: Endovascular prostheses ISO&nbsp;25539-2:2012:&nbsp;Cardiovascular implants \u2014 Endovascular devices \u2014 Part 2: Vascular stents The local compression test determines the deformation of the device in response to a localized compressive force and whether the stent recovers its original geometry after testing. Using a probe, the load is applied perpendicular&hellip;","_links":{"self":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/vi-stents-and-endova\/3515","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/vi-stents-and-endova"}],"about":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/types\/vi-stents-and-endova"}],"wp:attachment":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/media?parent=3515"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}