{"id":3495,"date":"2024-09-10T19:25:19","date_gmt":"2024-09-10T17:25:19","guid":{"rendered":"https:\/\/endolab.org\/?post_type=stent-delivery-sys&#038;p=3495"},"modified":"2025-04-07T17:04:41","modified_gmt":"2025-04-07T15:04:41","slug":"iso-25539-10","status":"publish","type":"stent-delivery-sys","link":"https:\/\/endolab.org\/de\/stent-delivery-sys\/iso-25539-10\/","title":{"rendered":"ISO\u00a025539"},"content":{"rendered":"<p><strong>ISO&nbsp;25539\u20101:<\/strong>&nbsp;Cardiovascular implants &#8211; Endovascular devices &#8211; Part 1: Endovascular prostheses<\/p>\n\n\n\n<p><strong>ISO&nbsp;25539\u20102:<\/strong>&nbsp;Cardiovascular implants &#8211; Endovascular devices &#8211; Part 2: Vascular stents<\/p>\n\n\n\n<p><strong>ASTM&nbsp;F2081:<\/strong>&nbsp;Standard Guide for Characterization and Presentation of the Dimensional Attributes of Vascular Stents<\/p>\n\n\n\n<p>This test evaluates the relationship between the stent diameter and the applied balloon inflation pressure.<\/p>\n\n\n\n<p>The pressure-diameter dependency is measured using a computerized two-axis positioning device in combination with a laser micrometer. &nbsp;<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":true,"_uag_custom_page_level_css":""},"class_list":["post-3495","stent-delivery-sys","type-stent-delivery-sys","status-publish","hentry"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Kilian Pallauf","author_link":"https:\/\/endolab.org\/de\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO&nbsp;25539\u20101:&nbsp;Cardiovascular implants &#8211; Endovascular devices &#8211; Part 1: Endovascular prostheses ISO&nbsp;25539\u20102:&nbsp;Cardiovascular implants &#8211; Endovascular devices &#8211; Part 2: Vascular stents ASTM&nbsp;F2081:&nbsp;Standard Guide for Characterization and Presentation of the Dimensional Attributes of Vascular Stents This test evaluates the relationship between the stent diameter and the applied balloon inflation pressure. The pressure-diameter dependency is measured using a&hellip;","_links":{"self":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/stent-delivery-sys\/3495","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/stent-delivery-sys"}],"about":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/types\/stent-delivery-sys"}],"wp:attachment":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/media?parent=3495"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}