{"id":3486,"date":"2024-09-10T19:17:03","date_gmt":"2024-09-10T17:17:03","guid":{"rendered":"https:\/\/endolab.org\/?post_type=stent-delivery-sys&#038;p=3486"},"modified":"2024-09-26T16:35:01","modified_gmt":"2024-09-26T14:35:01","slug":"astm-f2743","status":"publish","type":"stent-delivery-sys","link":"https:\/\/endolab.org\/de\/stent-delivery-sys\/astm-f2743\/","title":{"rendered":"ASTM\u00a0F2743"},"content":{"rendered":"<p><strong>ASTM&nbsp;F2743:<\/strong>&nbsp;Standard Guide for Coating Inspection and Acute Particulate Characterization of Coated Drug-Eluting Vascular Stent.<\/p>\n\n\n\n<p>The test standard describes in-vitro test procedures for assessing the acute coating durability of coated drug-eluting vascular stent systems. Clinical performance (i.e., drug elution) may be affected by coating durability. Balloon-expandable and self-expanding stents are included within the scope. Recommended practices for assessing acute coating durability include baseline (deployment) testing and simulated use testing. We provide several approaches for coating integrity assessment.<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":true,"_uag_custom_page_level_css":""},"class_list":["post-3486","stent-delivery-sys","type-stent-delivery-sys","status-publish","hentry"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Theresa Kaddick","author_link":"https:\/\/endolab.org\/de\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"ASTM&nbsp;F2743:&nbsp;Standard Guide for Coating Inspection and Acute Particulate Characterization of Coated Drug-Eluting Vascular Stent. The test standard describes in-vitro test procedures for assessing the acute coating durability of coated drug-eluting vascular stent systems. Clinical performance (i.e., drug elution) may be affected by coating durability. Balloon-expandable and self-expanding stents are included within the scope. Recommended practices&hellip;","_links":{"self":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/stent-delivery-sys\/3486","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/stent-delivery-sys"}],"about":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/types\/stent-delivery-sys"}],"wp:attachment":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/media?parent=3486"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}