{"id":3482,"date":"2024-09-10T19:14:02","date_gmt":"2024-09-10T17:14:02","guid":{"rendered":"https:\/\/endolab.org\/?post_type=stent-delivery-sys&#038;p=3482"},"modified":"2024-09-26T16:37:32","modified_gmt":"2024-09-26T14:37:32","slug":"iso-25539-astm-f2394","status":"publish","type":"stent-delivery-sys","link":"https:\/\/endolab.org\/de\/stent-delivery-sys\/iso-25539-astm-f2394\/","title":{"rendered":"ISO\u00a025539 \/ ASTM\u00a0F2394"},"content":{"rendered":"<p><strong>ISO&nbsp;25539\u20101:<\/strong>&nbsp;Cardiovascular implants &#8211; Endovascular devices &#8211; Part 1: Endovascular prostheses<\/p>\n\n\n\n<p><strong>ISO&nbsp;25539\u20102:<\/strong>&nbsp;Cardiovascular implants &#8211; Endovascular devices &#8211; Part 2: Vascular stents<\/p>\n\n\n\n<p><strong>ASTM&nbsp;F2394:<\/strong>&nbsp;Measuring Securement of Balloon Expandable Vascular Stent Mounted on Delivery System<\/p>\n\n\n\n<p>For the pre-mounted balloon-expandable implant, EndoLab<sup>\u00ae<\/sup>&nbsp;GmbH determines the force required to pull off the crimped implant from the non-expanded balloon. This test is conducted at the proximal and distal ends of the implant. &nbsp;<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":true,"_uag_custom_page_level_css":""},"class_list":["post-3482","stent-delivery-sys","type-stent-delivery-sys","status-publish","hentry"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Theresa Kaddick","author_link":"https:\/\/endolab.org\/de\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO&nbsp;25539\u20101:&nbsp;Cardiovascular implants &#8211; Endovascular devices &#8211; Part 1: Endovascular prostheses ISO&nbsp;25539\u20102:&nbsp;Cardiovascular implants &#8211; Endovascular devices &#8211; Part 2: Vascular stents ASTM&nbsp;F2394:&nbsp;Measuring Securement of Balloon Expandable Vascular Stent Mounted on Delivery System For the pre-mounted balloon-expandable implant, EndoLab\u00ae&nbsp;GmbH determines the force required to pull off the crimped implant from the non-expanded balloon. This test is conducted&hellip;","_links":{"self":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/stent-delivery-sys\/3482","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/stent-delivery-sys"}],"about":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/types\/stent-delivery-sys"}],"wp:attachment":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/media?parent=3482"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}