{"id":3480,"date":"2024-09-10T19:12:14","date_gmt":"2024-09-10T17:12:14","guid":{"rendered":"https:\/\/endolab.org\/?post_type=stent-delivery-sys&#038;p=3480"},"modified":"2025-04-09T15:14:33","modified_gmt":"2025-04-09T13:14:33","slug":"iso-25539-astm-f2081","status":"publish","type":"stent-delivery-sys","link":"https:\/\/endolab.org\/de\/stent-delivery-sys\/iso-25539-astm-f2081\/","title":{"rendered":"ISO\u00a025539 \/ ASTM\u00a0F2081"},"content":{"rendered":"<p><strong>ISO&nbsp;25539\u20101:<\/strong>&nbsp;Cardiovascular implants &#8211; Endovascular devices &#8211; Part 1: Endovascular prostheses<br><br><strong>ISO&nbsp;25539\u20102:<\/strong>&nbsp;Cardiovascular implants &#8211; Endovascular devices &#8211; Part 2: Vascular stents<br><br><strong>ASTM&nbsp;F2081:<\/strong>&nbsp;Standard Guide for Characterization and Presentation of the Dimensional Attributes of Vascular Stents<br><br>With the dimensional verification, the stent system geometry is determined. This can be used to verify the design specifications. The dimensions include but are not limited to, the outer diameter, guidewire lumen diameter, and useable length. The results can help to evaluate the dimensional compatibility between the stent system and the recommended accessory devices. &nbsp;<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":true,"_uag_custom_page_level_css":""},"class_list":["post-3480","stent-delivery-sys","type-stent-delivery-sys","status-publish","hentry"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Theresa Kaddick","author_link":"https:\/\/endolab.org\/de\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO&nbsp;25539\u20101:&nbsp;Cardiovascular implants &#8211; Endovascular devices &#8211; Part 1: Endovascular prostheses ISO&nbsp;25539\u20102:&nbsp;Cardiovascular implants &#8211; Endovascular devices &#8211; Part 2: Vascular stents ASTM&nbsp;F2081:&nbsp;Standard Guide for Characterization and Presentation of the Dimensional Attributes of Vascular Stents With the dimensional verification, the stent system geometry is determined. This can be used to verify the design specifications. The dimensions include&hellip;","_links":{"self":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/stent-delivery-sys\/3480","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/stent-delivery-sys"}],"about":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/types\/stent-delivery-sys"}],"wp:attachment":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/media?parent=3480"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}