{"id":3252,"date":"2024-09-10T10:31:39","date_gmt":"2024-09-10T08:31:39","guid":{"rendered":"https:\/\/endolab.org\/?post_type=mt-metal-analysis&#038;p=3252"},"modified":"2024-10-21T15:11:30","modified_gmt":"2024-10-21T13:11:30","slug":"iso-5832-3","status":"publish","type":"mt-metal-analysis","link":"https:\/\/endolab.org\/de\/mt-metal-analysis\/iso-5832-3\/","title":{"rendered":"ISO\u00a05832-3"},"content":{"rendered":"<p><strong>ISO&nbsp;5832-3:<\/strong>&nbsp;Implants for surgery &#8211; Metallic materials &#8211; Part 3: Wrought titanium 6-aluminium 4-vanadium alloy<br><br>This standard specifies the chemical composition, microstructure and mechanical properties (tensile and bending) of the widely used Ti6Al4V titanium alloy. Tolerances for the individual chemical elements as well as for the mechanical properties are provided. The test methods for microstructure (ISO&nbsp;20160, EN&nbsp;3114-003) and the mechanical properties (ISO&nbsp;6892-1, ISO&nbsp;7437) are referenced.<br><br>EndoLab<sup>\u00ae<\/sup>&nbsp;does provide our valued customers with the complete analysis as given by the standard. &nbsp;<\/p>","protected":false},"featured_media":0,"parent":0,"template":"","meta":{"_acf_changed":true,"_uag_custom_page_level_css":""},"class_list":["post-3252","mt-metal-analysis","type-mt-metal-analysis","status-publish","hentry"],"acf":[],"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"trp-custom-language-flag":false},"uagb_author_info":{"display_name":"Theresa Kaddick","author_link":"https:\/\/endolab.org\/de\/author\/"},"uagb_comment_info":0,"uagb_excerpt":"ISO&nbsp;5832-3:&nbsp;Implants for surgery &#8211; Metallic materials &#8211; Part 3: Wrought titanium 6-aluminium 4-vanadium alloy This standard specifies the chemical composition, microstructure and mechanical properties (tensile and bending) of the widely used Ti6Al4V titanium alloy. Tolerances for the individual chemical elements as well as for the mechanical properties are provided. The test methods for microstructure (ISO&nbsp;20160,&hellip;","_links":{"self":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/mt-metal-analysis\/3252","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/mt-metal-analysis"}],"about":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/types\/mt-metal-analysis"}],"wp:attachment":[{"href":"https:\/\/endolab.org\/de\/wp-json\/wp\/v2\/media?parent=3252"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}